BT110 & BT120 Boiler Controllers
- Product Details
- Specifications
- Installation
- Operation
CHEMTROL® BT110 Boiler Controller
Automatic blowdown and chemical feed for one boiler
The CHEMTROL® BT110 keeps boiler water within its conductivity (TDS) limit by opening the blowdown valve automatically, and runs up to three chemical feeds – inhibitors, biocides, dispersants and more – from one easy-to-use programmable controller.
It also monitors water temperature, calculates the Langelier Saturation Index for water balance and logs its readings automatically. Add web access to see and adjust it from your computer or phone.
Models
- BT110 – blowdown control for one boiler, conductivity up to 20,000 µS
- BT120 – condensate control, conductivity up to 2,000 µS
- BT112 – blowdown control for two boilers (see the BT112)
Compare the Models
| CHEMTROL® Model / Features | Boiler controllers | ||
|---|---|---|---|
| BT110 | BT112 | BT120 | |
| Control relay outputs | 6 | 6 | 6 |
| Conductivity control | 1 | 2 | 1 |
| Conductivity range | 20,000 µS | 20,000 µS | 2,000 µS |
| Temperature display | 1 | 2 | 1 |
| Blowdown control | 1 | 2 | 1 |
| Chemical feed programs | 3 | 3 | 3 |
| Chemical level alarm | ✓ | ✓ | ✓ |
| Langelier Saturation Index | ✓ | ✓ | ✓ |
| Alarms: audio, visual, external | ✓ | ✓ | ✓ |
| Automatic data logging | ✓ | ✓ | ✓ |
| Remote monitoring, web access | OPT | OPT | OPT |
✓ Included as standard OPT Optional extra, at additional cost
BT110 Specifications

Control
- Conductivity (TDS) control, with a choice of bleed programs
- High-temperature monitoring
- Langelier Saturation Index (LSI) calculated automatically, for water balance
Chemical feed
- Up to three chemical additives, such as inhibitors, biocides and dispersants
- Seven feed programs: manual, cycle timer, auto bleed-and-feed, auto bleed-then-feed, percent of flow, daily schedule and two-week schedule
- “Booster” program for a delayed, one-time feed
- Low chemical level alarm, standard, based on each feed outlet’s accumulated run time (a tank level sensor is purchased separately)
Measurement and records
- Differential signal amplification, for a steady reading
- 1, 2 or 3-point calibration
- Automatic data logging
Options
- OPTION pH (BT110) – pH monitoring with automatic acid or base control, including dynamic probe testing with a sensor failure warning
- OPTION COMM – remote operation and web access
BT110 Installation
The BT110 is straightforward to install, as the plumbing set-up below shows. Every controller comes with a detailed installation and operation manual.


BT110 Operation
Everything is set from the front panel. The LCD screen and keypad give direct access to every menu: sensor calibration, set points, alarm levels and the feed programs.
Remote Monitoring & Control
Every CHEMTROL® programmable controller can be monitored and controlled remotely, 24/7. Log in to our web-server from any browser to see the controller’s own display, or use the CHEMTROL app for Android and Apple.
Change settings in real time, check status reports and trend graphs, and receive alerts by email or text message – for one site or many. See remote monitoring and control.
Connect the controller by Ethernet cable, Wi-Fi, or a 4G or 5G router. Find out more: web-access options.