Looking for a quote or to discuss your needs?
You can also review the documentation for technical details and purchasing information.
Injection Quill Series
- Male-Male
- Male-Female
- Quill Assembly
- Installation
Injection Quills, Male-Male

Our U.S.-made injection quills carry the dosed chemical from the metering pump into the middle of the pipe, where the flow mixes it in quickly and evenly, away from the pipe wall. The male-male quill has male NPT threads at both ends: 1/2″, 3/4″ or 1″ into the process line, and the same size to the pump line.
Key Features
- In 316 stainless steel, PVC, CPVC, Kynar® (PVDF), Alloy 20 or Hastelloy® C-276, to suit the chemical
- QC series: built-in ball and spring check valve that stops backflow
- QB series: no check valve, for use with an external one
- Angled tip that spreads the chemical into the flow; wrench flats for easy fitting
- High temperature and pressure ratings in 316 SS, Alloy 20 and Hastelloy®
- Standard 70 mm insertion; custom lengths and diameters to order
All models and ratings: Male-Male Data Sheet.
Injection Quills, Male-Female

Our U.S.-made male-female quill screws into the process line with a 1/2″, 3/4″ or 1″ male NPT thread and takes the pump line in a 1/2″ female NPT connection, carrying the chemical into the middle of the pipe for even mixing.
Key Features
- In 316 stainless steel, PVC, CPVC, Kynar® (PVDF), Alloy 20 or Hastelloy® C-276, to suit the chemical
- QCFM series: built-in ball and spring check valve that stops backflow
- QBFM series: no check valve, for use with an external one
- Kynar® with a Teflon® ball also available
- Angled tip that spreads the chemical into the flow; wrench flats for easy fitting
- Standard 70 mm insertion; custom lengths and diameters to order
All models and ratings: Male-Female Data Sheet.
Injection Quill Assembly

For systems that cannot be shut down: the isolation ball valve closes off the line, so the metering pump or the check valve can be serviced while the plant keeps running. Each assembly joins a 70 mm injection quill, an isolation ball valve and an external ball and spring check valve, with a 1/2″ female NPT connection for the pump line.
Key Features
- Service the pump or check valve without shutting the system down
- Quill, isolation ball valve and check valve in one assembly
- Ball and spring check valve against backflow, tested to a 10 psi crack pressure
- In 316 stainless steel, PVC, CPVC, Kynar® (PVDF), Alloy 20 or Hastelloy® C-276, to suit the chemical
- Process connection 1/2″, 3/4″ or 1″ MNPT; pump connection 1/2″ FNPT
- Custom quill lengths to order
All models and ratings: Assembly Data Sheet.
Installing an Injection Quill
- Fit the quill below the horizontal centreline of the pipe, with its tip between the 4 o’clock and 8 o’clock positions.
- Choose the wetted material from the chemical’s safety data sheet and its chemical compatibility.
- Where the plant cannot be shut down, use the quill assembly, or a corporation stop to insert and withdraw the quill under pressure.