MixRite Water-Powered Dosing Pumps

Which MixRite?

Two answers find your MixRite: the chemical decides the version, the water flow decides the size.

2. Water flow through the line

The chemical decides the version

You will doseVersionWhat is differentMade in
Chlorine (sodium hypochlorite)CLViton seals, Hastelloy springs2.5, 3.5, TF-5, TF-10, TF-25
Acid for pH correction, stronger than 6%PVDFPVDF body, Aflas seals2.5, 3.5
Fertiliser or pesticideStandardMade for fertigationAll six
Livestock medicines, vitamins, vaccines, organic acidsPOEPDM sealsLF-1000, 2.5, 3.5, TF-5
Car wash detergents, wax, acids and alkalisCWAflas seals2.5, 3.5
Other industrial additivesCEPDM seals2.5, 3.5
Alkaline, foaming or chlorinated products in hard waterBypassInternal bypass2.5, 3.5
Peroxide, peracetic acid, chlorine dioxide, quats, othersAsk usTefen asks for these to be confirmed first

The water flow decides the size

MixRiteWater flowPressureDosingInlet and outlet
LF-10004 – 1,000 L/h0.2 – 4 bar0.2 – 2%¾″
2.510 – 2,500 L/h0.2 – 8 bar0.1 – 4%¾″ BSPT
3.510 – 3,500 L/h0.2 – 8 bar0.03 – 10%¾″ BSPT
TF-50.1 – 5 m³/h1 – 8 bar0.1 – 5%1″ BSPT or 32 mm
TF-100.1 – 10 m³/h1 – 8 bar0.1 – 5%1½″ BSPT or 50 mm
TF-250.2 – 25 m³/h1 – 8 bar0.1 – 5.5%2″ BSPT or 63 mm

Every MixRite runs on the water pressure alone, with no electricity, and doses in proportion to the water flow. Water temperature 4 – 40 °C. On/Off and air-release covers are available on every size.

Before dosing an aggressive chemical, check with us that it suits the pump; Tefen asks for this, and we will confirm the right version.

MixRite LF-1000

  • Water flow: 4 – 1,000 L/h
  • Water pressure: 0.2 – 4 bar
  • Dosing: 0.2 – 2% (1:500 – 1:50), or 0.2% fixed
  • Inlet and outlet: ¾″
  • Water temperature: 4 – 40 °C
  • Versions: Standard, PO (livestock)

Tefen’s smallest MixRite, now in its range in place of the MixRite 1: made for very low water use, such as the first days of a poultry flock. It works up to 4 bar and has no chlorine (CL) version; for chlorine at low flows, choose the MixRite 2.5 CL.


MixRite 2.5

  • Water flow: 10 – 2,500 L/h (from 7 L/h in the PO version)
  • Water pressure: 0.2 – 8 bar
  • Dosing: 0.1 – 0.9% (1:1000 – 1:111), 0.3 – 2% (1:333 – 1:50), 0.4 – 4% (1:250 – 1:25); fixed 0.2, 0.8 and 1%
  • Chemical injected: up to 100 L/h
  • Inlet and outlet: ¾″ BSPT
  • Water temperature: 4 – 40 °C
  • Versions: Standard, CL (chlorine), PVDF (acids), PO (livestock), C (industry), CW (car wash), bypass

MixRite 3.5

  • Water flow: 10 – 3,500 L/h (from 50 L/h for 1 – 10%)
  • Water pressure: 0.2 – 8 bar
  • Dosing: 0.03 – 0.2% (1:3333 – 1:500), 0.1 – 0.9%, 0.3 – 2%, 0.5 – 5% (1:200 – 1:20), 1 – 10% (1:100 – 1:10)
  • Chemical injected: up to 350 L/h
  • Inlet and outlet: ¾″ BSPT
  • Water temperature: 4 – 40 °C
  • Versions: Standard, CL (chlorine), PVDF (acids), PO (livestock), C (industry), CW (car wash), bypass

The widest dosing range of the MixRite pumps, and the only one dosing up to 10%.


MixRite PVDF – for acids

For dosing acids, such as for pH correction, Tefen makes the MixRite 2.5 and 3.5 with a PVDF body. Tefen recommends PVDF once the acid in the stock solution is stronger than 6%.

  • What is different: a PVDF body, for its resistance to corrosive chemicals, oxidation and UV; Aflas seals; a stainless steel and Hastelloy spring
  • MixRite 2.5 PVDF: 0.4 – 4% (1:250 – 1:25), up to 2,500 L/h
  • MixRite 3.5 PVDF: 0.1 – 0.9%, 0.3 – 2%, 0.5 – 5% and 1 – 10% (1:1000 – 1:10), up to 3,500 L/h (from 20 L/h at 0.5 – 5%, and 50 L/h at 1 – 10%)
  • Internal bypass: the 0.5 – 5% and 1 – 10% models have one, which Tefen says gives a longer life and higher chemical resistance
  • As the standard pumps: water pressure 0.2 – 8 bar, ¾″ BSPT, no electricity

Tefen’s brochure, MixRite 3.5 PVDF for Acidification, is in the downloads.


MixRite TF-5

  • Water flow: 0.1 – 5 m³/h
  • Water pressure: 1 – 8 bar
  • Dosing: 0.1 – 1% (1:1000 – 1:100), 0.2 – 2% (1:500 – 1:50), 0.5 – 5% (1:200 – 1:20)
  • Chemical injected: up to 250 L/h
  • Inlet and outlet: 1″ BSPT or 32 mm
  • Water temperature: 4 – 40 °C
  • Weight: 5 kg; legs available on request
  • Versions: Standard, CL (chlorine), PO (livestock)

MixRite TF-10

  • Water flow: 0.1 – 10 m³/h
  • Water pressure: 1 – 8 bar
  • Dosing: 0.1 – 1% (1:1000 – 1:100), 0.2 – 2% (1:500 – 1:50), 1 – 5% (1:100 – 1:20)
  • Chemical injected: up to 500 L/h
  • Inlet and outlet: 1½″ BSPT or 50 mm
  • Water temperature: 4 – 40 °C
  • Weight: 7.3 kg; legs available on request
  • Versions: Standard, CL (chlorine)

MixRite TF-25

  • Water flow: 0.2 – 25 m³/h
  • Water pressure: 1 – 8 bar
  • Dosing: 0.1 – 1% (1:1000 – 1:100), 0.3 – 2.5% (1:333 – 1:40), 1 – 5.5% (1:100 – 1:18)
  • Chemical injected: up to 1,375 L/h
  • Inlet and outlet: 2″ BSPT or 63 mm
  • Water temperature: 4 – 40 °C
  • Weight: 18.5 kg; on legs as standard
  • Versions: Standard, CL (chlorine)

Tefen

Tefen has been a leader in dosing and flow products since 1970. Tefen’s MixRite dosing pumps are the optimal cost-effective choice for diverse applications such as crop fertilisation, livestock medication, water disinfection, surface cleaning, car washing and more.

The company produces a quality line of dosing pumps, as well as a wide range of complementary fittings and flow products: PVDF flow fittings, and polypropylene, nylon and acetal fittings, quick release couplings and valves.


Benefits

The rising demand for better sanitation and hygiene requires exceedingly accurate and reliable chemical mixing and injection. The proportional MixRite pumps guarantee precise dosing of the disinfectants required for water treatment, independently of pressure and flow variations in water networks.

Connected to the water supply, this pump range offers precise mixing of the additive with water and allows easy and quick dose adjustment when required. Tefen MixRite dosing pumps are widely used in hospitals, restaurants, irrigation, car washing and supermarkets, and provide an ideal solution.

Installing a MixRite

  • Fit a filter (120 mesh, 130 micron) and a backflow preventer before the MixRite, as the local rules for the water supply require.
  • Install it with the water flowing in the direction of the arrows on the pump.
  • Hang the strainer at least 10 cm above the bottom of the additive tank.
  • Install it on a bypass line where the water flow is higher than the pump’s range, or the pump is not needed all the time.
  • Never install it above an acid container, and drain it when the temperature may fall below 4 °C.

For the full instructions, see the user manual for your MixRite in the downloads on this page.

On the water line (in line)

A typical MixRite installation on the water line: valve, filter, backflow preventer, pressure gauge, the MixRite, anti-siphon valve, pressure gauge and valve, with the additive tank below and the strainer 10 cm above its bottom; the pump upright, not on its side

On a bypass line

For a water flow higher than the pump’s range, or a pump not needed all the time.

A typical MixRite installation on a bypass line: the MixRite between two valves and two pressure gauges, beside a valve on the main line

Typical installations, for illustration only: Tefen’s drawings, from the MixRite user manual.

Spare seal kits for every size are in the Replacement Parts download.

MixRite TF25 Proportional Dosing Pump – How it works


MixRite 3.5 Proportional Dosing Pump – How it works


Tefen Tutorial: MixRite 2.5


Tefen Tutorial: MixRite 3.5


Tefen Tutorial: MixRite TF10


Tefen Tutorial: MixRite TF25