Wall-Mounted LED Level Displays and Controllers for Chemical and Water Tanks
The Icon Process Controls LevelPro® TVL and TVU show a tank’s level, read from a 4–20 mA level sensor, on a bright LED display, and switch pumps, valves and alarms from their relays. Each comes complete and ready to fit: display, IP67 (NEMA 4X) enclosure, polycarbonate faceplate and cable glands.
Two models are available:
- TVL – compact display with 20 mm LED digits (4 digits, 6-digit option); 2 relays, or 1 relay + 4–20 mA output
- TVU – large 57 mm multi-colour LED digits that change colour with the process, like a stack light; 4 relays, or 2 relays + 4–20 mA output; audible alarm; universal inputs
Which One?
The TVL suits a level reading beside the tank or in the plant room, with high and low setpoints for a pump or an alarm. Choose the TVU where the level must be read from across the site, where the colour should warn operators, or where more relays or other inputs (temperature, mV) are needed. Both power the level sensor (24 V DC), talk RS-485 Modbus RTU, and run on 85–260 V AC/DC, so 230 V AC directly, or on 24 V DC.
TVL & TVU Tank Level Displays Specifications
| Item | TVL | TVU |
|---|---|---|
| Display | LED, 4 digits (6-digit option), 20 mm high, red or green | LED, 4 digits, 57 mm high, multi-colour (red to green) |
| Displayed values | −999 to 9999 | −999 to 9999 |
| Brightness | 8 levels | 8 levels |
| Inputs | 0/4–20 mA; 0–5, 1–5, 0–10, 2–10 V | 0/4–20 mA; 0–10 V; 0–150 mV; Pt100, Pt500, Pt1000 RTD; thermocouple K, S, J, T, N, R, B, E |
| Outputs | 2 relays, or 1 relay + 4–20 mA | 4 relays (5 A, 250 V AC), or 2 relays + 4–20 mA |
| Audible alarm | – | Yes |
| Sensor supply | 24 V DC, max. 100 mA | 24 V DC, max. 100 mA |
| Communication | RS-485, Modbus RTU | RS-485, Modbus RTU |
| Accuracy | ±0.1% at 25 °C, ±1 digit | ±0.1% at 25 °C, ±1 digit |
| Power supply | 85–260 V AC/DC, or 19–50 V DC / 16–35 V AC | 85–260 V AC/DC, or 19–50 V DC / 16–35 V AC |
| Protection | IP67 (NEMA 4X) | IP67 (NEMA 4X) |
| Housing | Polycarbonate faceplate, ABS base, wall mounted | Polycarbonate faceplate, ABS base, wall mounted |
| Cable glands | 3 included | 6 included |
| Dimensions | 110 × 80 × 67 mm (110 × 105 × 67 mm with glands) | 230 × 140 × 96.5 mm |
| Operating temperature | 0 to +50 °C (−20 °C version available) | 0 to +50 °C (−20 °C version available) |
| Part numbers | TVL-550-1821 (2 relays), TVL-550-1829 (1 relay + 4–20 mA); TVL-550-1831 / -1839 for 24 V DC; add -6 for 6 digits | TVU-1421 (4 relays), TVU-1429 (2 relays + 4–20 mA) |
Applications
- Chemical storage and dosing tanks
- Water and wastewater treatment tanks
- Cooling water, chilled water and glycol tanks
- Irrigation and fertigation tanks
- A remote level display for a submersible, ultrasonic or radar level sensor
Key Features
- Bright LED display, 8 brightness levels
- Multi-colour display that changes with the level (TVU)
- Relay outputs for pumps, valves and alarms; 4–20 mA output option
- 24 V DC supply to power the level sensor
- RS-485 Modbus RTU
- Peak value detection and signal damping
- Push-button programming, optional remote
- IP67 (NEMA 4X) corrosion-free enclosure, cable glands included
- 85–260 V AC/DC or 24 V DC power