Chemtrol Australia Product - Submersion & In-Line pH/ORP DynaProbe

Looking for a quote or to discuss your needs?

You can also review the documentation for technical details and purchasing information.

Submersion & In-Line pH/ORP DynaProbe

Threaded pH and ORP Sensors for Hot, Aggressive Processes

DynaProbe® sensors are built for the toughest process applications: high temperatures and pressures, strong caustics and harsh industrial plants. Their sealed, solid-state Ag/AgCl reference cell is designed for a long service life in the most severe conditions, and they have been used for decades in pulp and paper, mining, petrochemical, food and beverage and wastewater plants.

These sealed pH or ORP (redox) sensors have an integral male NPT thread, to screw into a pipe tee for in-line measurement or onto a pipe for submersion.

  • Chem856st: Kynar® (PVDF) body, 3/4″ NPT, with a built-in guard.
  • Chem956st: Ryton® (PPS) body, 3/4″ NPT, with a built-in solution ground, up to 140 °C.
  • Chem873st: Ryton® (PPS) body, 1″ NPT, up to 140 °C and 10 bar, with an optional threaded guard.
  • Chem973st: as the Chem873st, with a built-in solution ground.
Chem856st Kynar®, 3/4″ NPT
Chem856st
Kynar®, 3/4″ NPT
Chem956st Ryton®, 3/4″ NPT, solution ground
Chem956st
Ryton®, 3/4″ NPT, solution ground
Chem873st · Chem973st Ryton®, 1″ NPT
Chem873st · Chem973st
Ryton®, 1″ NPT

Submersion & In-Line DynaProbe Specifications

ModelChem856stChem956stChem873stChem973st
Process thread3/4″ NPT3/4″ NPT1″ NPT1″ NPT
BodyKynar® (PVDF)Ryton® (PPS)Ryton® (PPS)Ryton® (PPS)
MeasurementpH or ORP (redox)
pH range0–14 pH
Temperature0–100 °C0–140 °C0–140 °C0–140 °C
Maximum pressure6.9 bar (100 psig) at 50 °C6.9 bar (100 psig) at 120 °C10 bar (150 psig) at 120 °C10 bar (150 psig) at 120 °C
Wetted materialsKynar®, Teflon®, glassRyton®, Teflon®, glassRyton®, Teflon® or wood, glassRyton®, Teflon® or wood, glass
ReferenceSealed solid-state Ag/AgCl
JunctionCoaxial or recessed porous Teflon®Recessed porous Teflon®Coaxial Teflon®, recessed Teflon® or wood
pH glass optionsRugged dome (standard); high-pH glass for pH 13 and aboveRugged dome; high-pH glass; flat bulb (with Teflon® junction, 100 °C)
Solution ground–Built in–Built in
Temperature compensation (option)Built in: Pt100, Pt1000 or 3 kΩBuilt in: Pt100, Pt1000, 3 kΩ or 301 Ω
CableIntegral, 2.1 m (7 ft) standard; Teflon® cable above 80 °CIntegral jacketed cable with solution ground and temperature leads, 2.1 m standardIntegral, 2.1 m (7 ft) standard; Teflon® cable above 80 °CIntegral jacketed cable with solution ground and temperature leads, 2.1 m standard
ConnectorsBNC; BNC with ferrule leads; or all ferrule leads

Applications

  • Pulp and paper
  • Mining and mineral processing
  • Petrochemical and chemical plants
  • Hot process water and condensate
  • Industrial wastewater and neutralisation

Key Features

  • Up to 140 °C (Chem956st, Chem873st, Chem973st)
  • Kynar® or Ryton® body with an integral 3/4″ or 1″ NPT thread
  • Solid-state reference for long life in severe service
  • Built-in solution ground on the Chem956st and Chem973st
  • Works with CHEMTROL® controllers and most pH and ORP instruments