The Pyxis FS-100 series are compact inline meters for small flows, from 0 to 3,000 mL/min, read to 1 mL/min. Ultrasonic pulses are timed travelling with the flow and against it; the gap between the two gives the flow rate, so nothing moves in the liquid path to wear or stick.
Each meter shows the flow rate and running total on its own colour screen, and sends the flow to a controller, PLC or DCS over 4–20 mA and RS-485 Modbus. A built-in temperature sensor corrects the reading as the liquid warms or cools.
- FS-100 – UPVC flow path, for water
- FS-101 – PPS and glass-filled polymer flow path, for corrosive aqueous solutions
Measures and Controls
Besides measuring, the meter can hold a flow you set. In flow-control mode its second 4–20 mA output drives a regulating valve, and a built-in PID loop opens or closes it until the flow matches the setpoint. If the flow can’t reach the setpoint within two minutes, the screen and status light turn red.
Specifications
| Item | FS-100 | FS-101 |
|---|---|---|
| Part Number | 54200 | 58542 |
| Fluid | Water | Corrosive aqueous solutions |
| Wetted Materials | UPVC, PPS, glass-filled polymer, epoxy, fluorine rubber | PPS, glass-filled polymer, epoxy, fluorine rubber |
| Flow Range | 0 – 3,000 mL/min | |
| Minimum Detectable Flow | 10 mL/min | |
| Resolution | 1 mL/min | |
| Maximum Error | ±10 mL/min or ±1% of reading, whichever is greater | |
| Measuring Principle | Ultrasonic transit time, with built-in temperature compensation | |
| Flow Path Bore | 5 mm | |
| Inlet / Outlet | ½" NPT | |
| Fluid Temperature | 4 – 49 °C (40 – 120 °F) | |
| Inlet Pressure | 0.5 – 6.9 bar (7.25 – 100 psi) | |
| Display | 1.44" colour screen, 128 × 128 pixels, with status light | |
| Analogue Outputs | Two isolated 4–20 mA: no. 1 flow rate; no. 2 regulating valve (flow-control mode only) | |
| Digital Output | Isolated RS-485, Modbus RTU | |
| Power Supply | 24 V DC, 2 W | |
| Operating Temperature | 0 – 50 °C (32 – 122 °F) | |
| Storage Temperature | −20 – 70 °C (−4 – 158 °F) | |
| Humidity | 5 – 95%, non-condensing | |
| Dimensions | 145 mm H × 50 mm W × 61.5 mm D | |
| Weight | About 600 g | |
| Protection | IP65 | |
| Approvals | CE, RoHS | |
| Cable | 1.5 m flying-lead cable with 7-pin female adapter (CE-FE-4.9) supplied | |
| Warranty | 13 months | |
Before using the FS-101 on a chemical, check its compatibility with CHEMTROL®: Pyxis publishes a separate chemical compatibility reference for the FS series.
Sample & Chemical Flow
Inline sensors and analysers on cooling and process water read correctly only with a steady sample flow. The FS-100 shows that flow at a glance, reports it to the controller, and with a regulating valve holds it steady when the line pressure changes. The FS-101 measures dosed chemical solutions, confirming what a dosing pump actually delivers; on a pulsing diaphragm pump, a pulsation damper ahead of the meter steadies the reading.
Key Features
- 0 – 3,000 mL/min, 1 mL/min resolution, detects from 10 mL/min
- Ultrasonic transit time: no moving parts in the flow path
- Built-in temperature compensation
- Colour screen with flow rate, running total and trend chart
- Green/red status light and adjustable high and low flow alarms
- Flow-control mode drives a 4–20 mA regulating valve to a setpoint
- Isolated 4–20 mA flow output and isolated RS-485 Modbus RTU
- FS-101 wetted parts for corrosive solutions
- Compact and panel-mounting, IP65
- 24 V DC, 2 W
Mounting
- Fit the meter upright, with the liquid flowing upwards through it.
- ½” NPT inlet and outlet. Inlet pressure 0.5 – 6.9 bar.
- To panel-mount, drill two 4.2 mm holes using the meter’s mounting plate as a template and fix with M4 screws.
Wiring
- Red: 24 V DC +
- Black: 0 V and 4–20 mA −
- White: 4–20 mA + no. 1, flow rate (default 4 mA = 0, 20 mA = 3,000 mL/min)
- Green: 4–20 mA + no. 2, regulating valve only – if unused, leave unconnected and tape the end
- Blue: RS-485 A
- Yellow: RS-485 B
- Silver: earth
Modbus defaults: address 95, 9600 baud, even parity.
Calibration