Chemtrol Australia Product - Radar Liquid Level Sensors

Looking for a quote or to discuss your needs?

You can also review the documentation for technical details and purchasing information.

Radar Liquid Level Sensors

Radar Liquid Level Sensors

Non-Contact 80 GHz Radar and Guided Wave Radar for Tanks up to 20 m

The Icon Process Controls LevelPro® radar sensors measure liquid level continuously in chemical storage tanks, sumps and process vessels. Radar is not affected by vapour, outgassing or temperature, so readings stay steady where ultrasonic sensors struggle.

Five sensors cover different tanks and sites:

  • ProScan® 3 – 80 GHz, non-contact, CPVC or 316 stainless steel, Bluetooth set-up
  • ProScan® LRT – 80 GHz, non-contact, LoRa wireless for remote and outdoor tanks
  • ProScan® 2 – 80 GHz, non-contact, PTFE antenna, general purpose or explosion-proof
  • ProScan® – 26 GHz, non-contact, for foam and vapour
  • MLR-70 – guided wave radar (contact), FEP-coated probe, for foam, condensate and turbulence

Mounting on Plastic and Dome-Roof Tanks

The SBF self-aligning bulkhead fitting rotates up to 20°, so the sensor can be aimed straight down even on a sloping dome roof. It is corrosion resistant and made for plastic tanks.

Radar Liquid Level Sensor Specifications

ItemProScan® 3ProScan® LRTProScan® 2ProScan®MLR-70
TypeNon-contactNon-contact, LoRa wirelessNon-contactNon-contactContact (guided wave)
Frequency80 GHz80 GHz80 GHz26 GHz–
ClassificationGeneral purposeGeneral purposeGeneral purpose or explosion-proofGeneral purposeGeneral purpose or explosion-proof
Range10 m (20 m optional)10 m (20 m optional)10 m (20 m optional)10 m15 m
Output4–20 mA, RS-485LoRa, 4–20 mA4–20 mA, RS-4854–20 mA, RS-4854–20 mA, HART
EnclosureCPVC or 316 stainless steelCPVCGFPP or explosion-proofGFPP or explosion-proofPowder-coated aluminium alloy
DisplayLCD or blindBlindLCDLCDOLED
AntennaPPPPPTFE or 316 stainless steelPTFE or 316 stainless steelFEP-coated probe
Process ConnectionNPTNPTNPTNPTG thread
Power Supply24 V DC

Applications

  • Liquid chemical storage tanks
  • Chemical sumps
  • Water and wastewater tanks
  • Remote and outdoor tanks without cabling (ProScan® LRT)
  • Tanks with foam, vapour, condensate or turbulence
  • Hazardous areas (explosion-proof models)

Key Features

  • 80 GHz radar for a narrow beam and high accuracy
  • Not affected by vapour, outgassing or temperature
  • Ranges of 10 m as standard, 20 m optional (MLR-70: 15 m)
  • Loop-powered 2-wire 4–20 mA; RS-485, HART or LoRa wireless by model
  • Bluetooth set-up (ProScan® 3 and LRT)
  • LCD, OLED or blind versions
  • CPVC, 316 stainless steel or explosion-proof enclosures
  • Works under vacuum and at high pressure (ProScan® 3)
  • NEMA 4X / IP68 protection (ProScan® 3)
  • 24 V DC supply