Benefits:
- Self-priming – even against maximum line pressure. By-pass valves are not required. Cannot vapor lock or lose prime. 30ft of suction lift. Gentle low shear pumping action.
- Tube Failure Detection (TFD) senses tube rupture by detecting chemical in the pump head. No false triggering – Patented
- Optional dual channel tube design for optimum performance and pressure capability
Communication and Interface:
- Operator friendly digital controls with backlit LCD displays motor speed, input signal values, service, and alarm status
- Inputs include: 4-20mA and pulse inputs for remote external speed control and either powered 6-24 VDC or non-powered dry contact closure for remote start/stop
- Outputs: one 250V/3A relay to monitor TFD (Tube Failure System) and FVS (Flow Verification System), one 4-20mA analog signal scalable to the motor speed and one relay output for run status
- Compatible with Blue-White’s output Flow Verification Sensor (FVS) system. Sensor is sold separately
Superior Design:
- 5 Year Warranty
- 200:1 turndown ratio
- NEMA 4X (IP66) wash-down, chemically resistant powder coated enclosure
- Heavy duty rotor means no flexing and increased accuracy with no metal springs or hinges to corrode.
Safety Features:
- Tube Failure Detection (TFD) senses tube rupture, preventing hazardous chemical spills
Optional Components Available:
- Mounting Extended Brackets (72000-380) – 1 Pair, SS, 4 SS Screws
What’s Included:
- M2 Peristaltic Metering Pump
- Two tube assemblies
- Tube installation tool
- Mounting hardware kit
FLEXFLO® M2 Peristaltic Metering Pump
Max Feed: .02 – 17.2 GPH (.07 – 65.1 LPH)
Max Pressure: 125 PSI (8.6 bar)
Maximum working pressure (excluding pump tubes): | 125 psig (8.6 bar) Note: see individual pump tube assembly maximum pressure ratings. |
Max. fluid temperature (excluding pump tubes): | 3/8” OD x 1/4” ID tubing connections: 130 F (54 C) M/NPT connections: 185 F (85 C) Note: see individual pump tube assembly maximum temperature ratings |
Ambient Operating Temperature: | 14 F to 115 F (-10 C to 46 C) |
Ambient Storage Temperature: | -40 F to 158 F (-40 C to 70 C) |
Maximum fluid viscosity: | 12,000 Centipoise |
Maximum suction lift: | 30 ft. Water at sea level (14.7 atm psi) |
Operating Voltage: | 115VAC/60Hz, 1ph (1.5 Amp Maximum) 230VAC/60Hz, 1ph (0.7 Amp Maximum) 220VAC/50Hz, 1ph (1.0 Amp Maximum) 240VAC/50Hz, 1ph (1.0 Amp Maximum) |
Power Cord: | 240V50Hz = AS 3112 (Australia/New Zealand) |
Motor: | Brushed DC, 1/8 H.P. |
Duty cycle: | Continuous |
Motor speed adjustment range 200:1: | 1.0% – 100% motor speed (1.3 to 130 RPM) |
Motor speed adjustment resolution: | 0.1% increments |
Display: | Backlit LCD, UV resistant |
Keypad: | Eight button positive action tactile switch keypad |
Enclosure: | NEMA 4X (IP66), Polyester powder coated aluminum |
Maximum Overall Dimensions: | 19 W x 26 H x 35.6 D cm |
Product weight: | 12.9 Kg |
Approximate shipping wt: | 15.9 Kg |
Tube Failure Detection (TFD) System
Patent No. 7,001,153 and 7,284,964
No False Triggering!
Breakthrough technology for Peristaltic Pumps.
The TFD system will detect a wide range of chemicals (i.e. chlorine, acids, soaps, etc.). This unique technology was designed NOT to false trigger by condensation and washdown. Many companies require the TFD system for their peristaltic pumps.