Active Chlorine ppm Specifications

Spec.Active chlorine
(hypochlorous acid) HOCl
Hot Water SystemsIndustrial Water
ApplicationsDrinking water
Swimming pool water
Water of similar quality
Process Water
Charged water
Polluted water
Process Water
Charged water
Polluted water
Measuring range
0 – 002 ppm (PPMAC002)
0 – 010 ppm (PPMAC010)
0 – 002 ppm (PPMAC002HP)
0 – 010 ppm (PPMAC010HP)
0.5 – 100 ppm (PPMAC100)
0.5 – 200 ppm (PPMAC200)
pH range
5.5 – 8 pH
5 – 9 pH
5.5 – 8 pH
Temperature range
5 – 50°C
(with temperature compensation)
40 – 50°C
(with temperature compensation)
5 – 50°C
(with temperature compensation)
Disturbance by other oxidants
Free from isocyanuric acid
Chlorine dioxide (4x)
Chlorites
Ozone (9x)
Free from isocyanuric acid
Maximum pressure and flow rate
3 bar
Mini : 20 l/h
Maxi : 100 l/h
Recommended : 30 l/h
8 bar
Mini : 20 l/h
Maxi : 100 l/h
Recommended : 30 l/h
1 bar
Mini : 20 l/h
Maxi : 100 l/h
Recommended : 30 l/h
Start-up time and final calibration
First calibration after 2 hours
After 24 hours
First calibration after 2 hours
After 24 hours
First calibration after 2 hours
After 24 hours
Membrane lifetime
Approximately 1 year (depending on water quality/concentration)Approximately 1 year (depending on water quality/concentration)
Approximately 1 year (depending on water quality/concentration)
Material and type of protection
PVC black
IP 65
PPE Beige
IP 65
PVC black
IP 65
Power supply and output signal
16 – 24 VDC
4-20 mA
10 – 25 VDC
4-20 mA
16 – 24 VDC
4-20 mA