Chemtrol Australia Product - PULSAtron Series C Metering Pumps

Looking for a quote or to discuss your needs?

PULSAtron Series C Metering Pumps

PULSAtron Series C Metering Pumps

Simple, fixed-speed dosing up to 5.6 bar

The PULSAtron Series C is the simplest of the range: the pump runs at a fixed stroke rate and the dose is set by turning the stroke length, even while it runs. Options add external pacing, a prime button or auto/manual switch, and a low-level input.

Four models, from 0.9 L/h at 5.6 bar to 4.7 L/h at 5.6 bar.

Control

  • Stroke length, adjustable while running (10:1); fixed stroke rate
  • Option: external pacing
  • Option: momentary prime button or auto/manual switch
  • Option: low-level input, to protect the prime

Not sure which series suits you? Compare all PULSAtron series, or use our Dosing Pump Selector.

PULSAtron Series C models

ModelMax flow (L/h)Max pressure (bar)Strokes/minTubing connection
LC020.95.61251/4" ID × 3/8" OD or 3/8" ID × 1/2" OD
LC031.95.61251/4" ID × 3/8" OD or 3/8" ID × 1/2" OD
LC043.85.61251/4" ID × 3/8" OD or 3/8" ID × 1/2" OD
LC544.75.61251/4" ID × 3/8" OD or 3/8" ID × 1/2" OD

Engineering data

  • Pump head: GFPPL, PVC, PVDF or 316 stainless steel
  • Diaphragm: PTFE-faced, CSPE-backed
  • Check valves: Seats and O-rings in PTFE, CSPE or Viton; balls in ceramic, PTFE, 316 stainless steel or Alloy C
  • Fittings: GFPPL, PVC or PVDF
  • Viscosity: Up to 1,000 cP as standard; up to 3,000 cP with the larger connections and 316 stainless steel balls
  • Power: 230 VAC or 115 VAC, 50/60 Hz, single phase
  • Approvals: ETL listed, NSF/ANSI 50; PVDF and PVC degassing heads certified to NSF/ANSI/CAN 61 & 372; CE
  • For sodium hypochlorite, choose a PVC liquid end

Simple Dosing

For straightforward, low-pressure dosing where the dose is set once and left alone. Add the low-level input and the pump stops before the chemical tank runs dry, so it never loses its prime.

Key Features

  • Dose set by stroke length, adjustable while running
  • Optional low-level input stops it losing its prime
  • Repeatable to within ±3% of maximum capacity
  • Reliable timing circuit, protected against voltage and current surges
  • Fuse on the front panel
  • Solenoid protected by a self-resetting thermal overload
  • Water resistant, for indoor and outdoor use
  • Guided ball check valves, for less back-flow and easy priming
  • Leak-free bleed valve, for safe and easy priming
  • Sealless liquid end; rated for continuous duty


PULSAtron Series Metering Pumps – Installation


PULSAtron – How To Change The KOPkit