CHEM-FEED Plastic Single Skid

CHEM-FEED Plastic Single Skid

Compatible with: ProSeries® Metering Pumps: Flex-Pro® and Chem-Pro®

Mounting Positions: Floor or Wall


√  Single pump and dual pump systems

√  Leak free, threadless connections

√  Flow indicator

√  Optional Chemical Feed Flowmeter

√  Built-in spill containment

√  Ships fully assembled

Chem-Feed Engineered Skid Systems 

Skid Frame
Chemically resistant polyethylene structure. Welded joint constructionMaximum working pressure
150 psig (10.3 bar)
Operating Temperature14 F to 115 F (-10 C to 46 C)
Seals
FKM seals (optional EPDM)
Y Strainer (S)
PVC body, 1/32” Mesh
Universal mounting blocks
PA 12
Pump extended mounting brackets
316 Stainless Steel
Skid mounting foot pads
316 Stainless Steel
Tubing clamps
300 series SS band, 400 series SS screw
Unions (U)
PVC body, schedule 80
Ball valves (V)
True unions, PVC body, PTFE shaft bearings and seats
Pulsation Dampener (PD)
CPVC body, 10 cubic inch volume
Check Valve (CV)
PVC body. Cracking pressure: 1.0-1.5 psi. Maximum working pressure:
inlet = 150 psi, back = 100 psi.
Flow Indicator (F)
Machined cast acrylic, PVC connections, ceramic ball, PVDF ball stop, PVC half unions.
Pressure Relief Valve (PRV)
PVC body, PTFE primary diaphragm seal. Non-wetted components: EPDM
secondary seal, zinc plated steel spring, stainless steel external hardware,
HDPE pressure adjustment screw. Infinite adjustment from 10-150 psi.
Calibration Cylinder (CC)
PVC body, PVC end caps, 1/2” PVC pipe outlet vent.
Available volumes: 1.6 GPH (100ml), 4 GPH (250ml), 8 GPH (500ml), 16
GPH (1000ml), 32 GPH (2000ml), and 64 GPH (4000mL).
Gauge w/guard (G)
Gauge: liquid filled stainless steel with blowout plug, bottom mount, 1/4”
NPT theads. Available pressure ranges: 0-30 psi, 0-100, psi, 0-200 psi.
Guard: PVC body, temperature compensated oil filled.
Tubing (T)
Reinforced braided PVC, 200 psi max, meets NSF std. 51. The pump inlet
and outlet flexible tubing connections are terminated to half unions and
secured to the barbed fitting with stainless steel clamps.
Pump (sold separately)
FLEXFLO® model A1, A2, A3, or A4 peristaltic pumps
CHEM-FEED® model CD1, C2, C3, or CD3 diaphragm pumps
PipingSingle Skid: 1/2” PVC Schedule 80 (optional CPVC).
Duplex Skid: 1” Inlet & 1/2” Outlet PVC Schedule 80 (optional CPVC).
Triplex Skid: 1” Inlet & 1/2” Outlet PVC Schedule 80 (optional CPVC).
Mounting hardware
18-8 Stainless Steel
Single Pump System
– Wall or Floor mounting acceptable
Duplex Pump System
– Wall or Floor mounting acceptable
Triplex Pump System
– Floor mounting only acceptable
Approximate Shipping Weight
Single Pump System
– Standard: 80 lb. (36 Kg)
– With Mounted Pump: 140 lb. (64 Kg)
Duplex Pump System
– Standard: 120 lb. (54 Kg)
– With Mounted Pumps: 240 lbs (109 Kg)
Triplex Pump System
– Standard: 200 lb. (91 Kg)
– With Mounted Pumps: 380 lbs (172 Kg)

CHEM-FEED® Engineered Skid Systems were designed and engineered using solid modeling tools for superior piping installation and easy component maintenance. Custom engineered universal mounting blocks provide for easy component servicing and replacement.

Benefits:

  • Straightforward chemical feed skid: easy to order, ready to install, 2-week lead-time
  • Visual flow indicator for visual confirmation that chemical is flowing
  • All installed components are isolated with ball valves for easy maintenance

Superior Design:

  • Constructed out of strong Chemical/UV resistant polyethylene
  • Heavy duty wall and floor mounting brackets included
  • Optional chemical feed flowmeter to precisely measure chemical output from the metering pump
  • Optional local wiring connections, easy-to-access power and inputs/outputs

Safety Features:

  • Threaded plug for cleaning and spill diversion in drip containment reservoir
  • Ball valves are vented for operator safety
  • Leak-free threadless connections to ensure leak-free chemical feed

Standard

  • Pressure Relief Valve – Protects the system from over-pressurization, 10-150 psi setting range, 150 psi maximum system pressure
  • Check Valve – Protects the user from back-flow during pump maintenance
  • Flow Indicator – Provides a visual indication of chemical movement through the system
  • Inlet Y Strainer – Recommended for Diaphragm Pump systems

Optional components (see product matrix)

  • Calibration Cylinder – Confirm pump output under system conditions. Specify cylinder
  • volumes from 1.6 GPH to 64 GPH.
  • Pulsation Dampener – Protect the system components from pulsation. Recommended for diaphragm pump systems only
  • Pressure Gauge with Guard – Isolate and protect the system pressure gauge. Specify
  • pressure ranges from 0-30 psi, 0-100psi, or 0-200 psi
  • S6A Chemical Flowmeter – Provides 4-20mA and pulse output data to SCADA and to the pump to verify chemical feed
  • Terminal Box: Pumps pre-wired for easy access to all electrical signal wires
  • Electrical Outlet Box: Designed for use in wet, damp, or dry locations